Frigidaire Dishwasher Error Code i10: Low Water Fill Level / Timeout During Intake
The electronic pressure sensor detects that the water level in the sump basin failed to reach minimum operating threshold within the allotted fill period.
dishwasher
OEM Certified Technical Diagnostic Tree
Digital Multimeter
Measure Ohms resistance, continuity & line voltage.
Advanced Diagnostic
4 Sequential manufacturer inspection branches.
Sequential Factory Diagnostic Tree
Perform each diagnostic step in order. Disconnect electrical power and turn off utility shutoffs before inspecting wiring or internal mechanical assemblies.
Clear plumbing shutoff valve restriction or replace kinked stainless hose.
Proceed to Step 2.
Clean or replace water inlet valve assembly (5304517886).
Proceed to Step 3.
Open or shorted solenoid coil. Replace water inlet valve (5304517886).
Proceed to Step 4.
Clean diaphragm or replace pressure transducer (5304504077).
Replace main electronic control board (5304512731).
Verified OEM Replacement Parts
Cross-referenced factory part numbers for Frigidaire dishwasher error code i10. Always replace defective components with authentic OEM parts to maintain UL safety certification.
| Component Name | OEM Part Number | Manufacturer | Status |
|---|---|---|---|
| Water Inlet Solenoid Valve Assembly | 5304517886 | Frigidaire | Direct Fit OEM |
| Electronic Water Level Pressure Sensor | 5304504077 | Frigidaire | Direct Fit OEM |
| Main Electronic Control Board | 5304512731 | Frigidaire | Direct Fit OEM |
Connect with a Certified Frigidaire Technician in Your Area
If multimeter testing reveals an internal short, locked motor, or fried control board, let an experienced local technician complete the repair with certified OEM replacement parts.
Frequently Asked Questions: Frigidaire i10
What causes Frigidaire dishwasher error code i10?
The electronic pressure sensor detects that the water level in the sump basin failed to reach minimum operating threshold within the allotted fill period.
Can I reset the i10 code by unplugging the dishwasher?
While disconnecting power for 5 minutes may temporarily clear the display control memory, the i10 code will reoccur once the microcontroller detects the mechanical or electrical fault again.
What OEM replacement parts are required for Frigidaire i10?
Common OEM replacement components include: Water Inlet Solenoid Valve Assembly (OEM #5304517886), Electronic Water Level Pressure Sensor (OEM #5304504077), Main Electronic Control Board (OEM #5304512731).